01 / OPERATIONS / COLOCATION / COMPUTE

Data Center Operators & Customers

Connect compute demand, thermal behavior and cooling decisions across your operating context.

For facility operators, enterprise teams and colocation customers, the starting point is the same: understand the signals you can access and the decisions you can influence.

01 / RELEVANCE

Where thermal context helps.

Less cooling energy

Evaluate cooling demand against the workload and thermal conditions it serves. A useful comparison starts with an agreed baseline and suitable cooling measurements.

Predictive Maintenance

Investigate changing thermal behavior in the context of compute load and cooling state. Use that context to guide maintenance questions and targeted investigation.

Full Transparency

Keep measurement sources, model assumptions and proposed actions visible to the people responsible for operations.

02 / WHAT YOU RECEIVE

What a first evaluation produces.

A signal inventory

The temperature, load and cooling signals your systems provide, with measurement location, update rate and data quality. It also names the gaps that limit an evaluation.

A model comparison on your data

Predictions of the thermal model set against your recorded operation, including load changes. The result states where the model fits and where its uncertainty increases.

A baseline you can check

An agreed system boundary, comparison period and set of documented conditions. A later statement about cooling energy can then be traced back to its measurements.

Recommended control inputs

Calculated setpoints, such as coolant supply temperature and flow, presented with the limits they respect. They are reviewed as recommendations first. Direct actuation is a separate, explicitly approved step.

03 / INPUT DATA

The signals we work with.

Compute
Power draw, utilization and component temperatures per server or accelerator
Shows a load change when it happens and the margin to component limits.
Cooling loop
Supply and return temperatures, flow and pressure
Describes how heat leaves the IT equipment and what the control inputs change.
Cooling plant
Operating state and electrical power of pumps, fans and chillers
Required for any statement about cooling energy.
Environment
Inlet and outdoor temperatures
Makes two operating periods comparable.

Server telemetry typically comes from accelerator management tools and baseboard management controllers, cooling data from the facility or cooling-distribution systems. Which values exist, and how often they update, depends on your equipment. Not every group has to be available on day one.

04 / WORKING TOGETHER

Start with your operating question.

  1. Map responsibility and access

    Separate facility, cooling and tenant responsibilities. Establish which signals are available and who can approve access or operating changes.

  2. Agree what to evaluate

    Choose the operating questions, comparison period and measurement boundary. Review model behavior against the available recorded data.

  3. Define the next operating step

    Agree whether the project should provide analysis, recommendations or a separately approved control integration, together with limits and fallback behavior.

05 / FIRST CONVERSATION

Bring your context.

  • Do you operate the cooling system, the compute infrastructure, or both?
  • Which temperature, workload and cooling-power measurements can you access?
  • Which maintenance or cooling decision would a pilot need to support?
Discuss your operating context